Can an older slate roof take solar panels? A South West London case study

We were asked to inspect a house in South West London where the owner wanted to install solar panels. Before going ahead, they needed to answer two questions. What condition was the roof in, and how much usable space was there for panels?

From ground level, it was difficult to see the condition of the slates or judge how much space the rooflight and valley left. We used a drone to capture close-up images of the roof covering and produce approximate measurements of the proposed installation area. That gave the owner, surveyor and installer a record they could all work from.

What did the drone inspection show?

The slate covering looked aged, with visible weathering and unevenness across parts of the slope. The aerial images also showed the relationship between the proposed panel area, the rooflight and the diagonal valley, where water drains between the two roof slopes.

That matters because once panels are in place, access to the slates beneath them becomes more difficult. If the covering is already approaching the point where it needs local repairs or renewal, it makes sense to assess that before fitting panels. Otherwise, some of the array might have to come off again to carry out roofing work. The close-up images help a roofer see where to focus that assessment.

What would the panels add to the roof?

For an idea of weight, one manufacturer’s 440 W residential panel weighs 22 kg. Two panels of that type would weigh 44 kg before rails and fixings. The final load depends on the equipment selected and how it’s mounted. The installer also needs to consider wind uplift and how the fixings transfer loads into the roof structure.

The drone survey recorded the visible condition of the covering and the area where the array might sit. Confirming whether the roof can carry the proposed installation requires checking the supporting structure and fixing points. On an older roof, that’s a separate decision from whether the slates need attention.

Illustrative two-panel layout based on drone measurements. Final panel fit and clearances to be confirmed by the installer.

How many panels could fit?

The measured section was approximately 4.78 m across the upper edge and 3.93 m across the lower edge. The shorter side measured 1.86 m, and the diagonal edge along the valley measured 2.15 m. That taper makes a difference. A single width measurement would miss how much space the valley takes away towards the bottom of the roof.

We used those dimensions to sketch two landscape panels below the rooflight, allowing for a gap between the modules. The trial layout assumes panels measuring 1,722 × 1,134 mm. A third panel is worth exploring with a shorter module, once the installer has checked the usable depth and the clearances around the valley, rooflight and roof edges.

What would make this roof a good candidate for solar?

A good candidate has a sound covering, a structure suitable for the mounting system and enough clear roof area for the panels. For generation, a largely unshaded, south-facing pitched roof is a good starting point, although east- and west-facing roofs can also work well. Chimney shade, roof direction and pitch all affect output. The aerial images show where those obstructions are, giving the installer a starting point for a site-specific yield estimate.

As an illustration, two 440 W panels would give a 0.88 kWp array. Using a London generation benchmark, that works out at around 800 kWh a year. The actual figure for this roof will depend on orientation, pitch and shading.

What did the owner gain from the survey?

The owner could see the condition of the slates, understand why the usable space was smaller than it looked, and give the roofer and installer a measured starting point. They could then decide whether roofing work should come first and whether a small solar array was worth taking forward.

If you’re considering solar panels on an older or hard-to-access roof, CAV Aerial can document the visible roof condition and measure the proposed installation area before you commit to the work.